Commander C200 C200-05400300A Variable Frequency Drive
15 kW
Power
400V
Supply
30.0A
Output current
Fr.05
Frame size

C200-05400300A
15 kW 400V Variable Frequency Drive

15 kW / 20 HP 400V Supply 30.0A Output Frame 05 General PurposeWide Voltage
ℹ️
Commander C200 — General Purpose Drive
The C200 is optimised for cost-effective speed control of standard motors (pumps, fans, conveyors). For precision position control and shuttle AS/RS axes, specify the Unidrive M700 instead.

Quick answer: The C200-05400300A is a Control Techniques Commander C200 rated at 15 kW (20 HP) for 380–480V ±10%, 3-phase supply with 30.0A output. General Purpose AC Drive — Wide Voltage Range, 100V to 690V. Frame 05, IP20.

Technical Specifications

Electrical
Model NumberC200-05400300A
SeriesCommander C200
Power Rating15 kW (20 HP)
Output Current30.0 A
Overload CapabilityNormal Duty (110% / 60 s)
Supply Voltage380–480V ±10%, 3-phase
Output Frequency0–3,200 Hz (M702) / 0–1,000 Hz (C200/C300)
Mechanical
Frame SizeFrame 05
Dimensions (H×W×D)H: 455 mm × W: 185 mm × D: 230 mm
Protection RatingIP20 / UL Type 1
Ambient Temperature-10°C to +50°C (derate above 40°C)
Storage Temperature-40°C to +60°C
Safety & Communications
Safety FunctionsSTO (Safe Torque Off) — PL-d / SIL 2
CommunicationsOptional: Profibus-DP, CANopen, EtherNet/IP, Modbus RTU, DeviceNet

Quick Quote

Formal RFQ Form
24-hour quote response
FOB / CIF / DDP available
English / Russian / Chinese

Applications

  • Pump and fan speed control (HVAC, water treatment)
  • Conveyor belt drives (simple speed control)
  • Compressors and mixers
  • General material handling and packaging machines
  • Machine-tool auxiliary drives

Common Fault Codes & Remedies

Applicable to Control Techniques C200 series. Always isolate supply before investigating faults.

Fault Name Cause & Remedy
Err 3OvercurrentOutput short circuit or undersized drive. Check motor wiring, increase acceleration ramp (Pr 0.03), verify drive current rating ≥ motor FLC.
Err 7OvervoltageRegenerative load without braking resistor, or deceleration too fast. Add braking resistor, increase deceleration time (Pr 0.04).
Err 4UndervoltageSupply voltage below threshold. Check incoming supply, verify supply stability under load.
Err 15Drive overtemperatureHeatsink overheated. Check ambient temp (max 40°C), clean filters, verify fan operation, reduce switching frequency.
Err 23Motor overtemperaturePTC thermistor tripped or motor I²t limit exceeded. Check for mechanical jam, verify motor cooling, check PTC wiring.
Err 27Supply lossOne or more input phases lost. Check supply connections, verify 3-phase symmetry, check incoming fuses.
Err 46STO activeSafe Torque Off input opened. Check safety circuit wiring to STO terminals, verify safety relay output.
Err 1Phase loss (output)Open circuit on output — motor cable disconnected. Check motor connection and cable continuity.
Err 12Fieldbus timeoutProfinet / EtherNet/IP communication lost. Check Ethernet cable, verify PLC watchdog settings, check IP configuration.
Err 29Brake IGBT faultBraking IGBT over-temperature or short circuit. Check braking resistor connection and resistance value.